OMNIK-error codes
Below you will find a list of common error messages from various brands. Not all error messages are listed here. It is advisable to also consult the manual of the device.Brand | Error code | Cause | Action |
---|---|---|---|
Omnik | Ground I Fault | GFCI failure oversized leakage current | Please check the DC wiring and measure. If you consider the wiring to be in order, Contact inverter service |
Omnik | Fac Failure | Grid frequency failure | Please check the AC wiring and measure. If you consider the wiring to be in order, Contact inverter service |
Omnik | Vac Failure | Grid voltage failure | Please check the AC wiring and measure. If you consider the wiring to be in order, Contact inverter service |
Omnik | Utility Loss | No Utility&Island | Please check the AC wiring and measure. If you consider the wiring to be in order, Contact inverter service |
Omnik | PV Over Voltage | Input voltage too high | Please check the DC wiring and measure. If you consider the wiring to be in order, Contact inverter service |
Omnik | Over Temperature | Temperature abnormal | Check the inverter for heat build up or blockage of the cooler ribs and rectify as required. If this does not correct the problem, Contact inverter service |
Omnik | Isolation Fault | Isolation failure | Check system isolation. If you consider the isolation impedance to be in order, Contact inverter service |
Omnik | Relay-Check Fail | Output relay failure | If problem occurs repeatedly, Contact inverter service |
Omnik | DC INJ High | Output DC injection too high | If problem occurs repeatedly, Contact inverter service |
Omnik | EEPROM R/W Fail | EEPROM problem | If problem occurs repeatedly, Contact inverter service |
Omnik | SCI Failure | Serial communication interface failure | Please Contact inverter service |
Omnik | AC HCT Failure | Output AC sensor abnormal | If problem occurs repeatedly, Contact inverter service |
Omnik | GFCI Failure | GFCI testing device abnormal | If problem occurs repeatedly, Contact inverter service |
Omnik | /W Updating | Update | If problem occurs once only: wait for the regulator to be come stable again. If problem occurs repeatedly: please Contact inverter service |
Omnik | Reconnect s | Reconnect | This text is displayed for information purposes only. |
Omnik | Checking s | Checking | This text is displayed for information purposes only. |
Omnik | Waiting | Initialization & waiting | This text is displayed for information purposes only. |
Kontaktieren Sie uns
Address
Tramstraat 7, 8560 Wevelgem
Phone
+32 (0)56 18 58 48
info@wechselrichterservice.be