BrandError codeCauseAction
SMAInterferrenceInternal faultContact inverter service
SMADI MEASInstallation problemCheck the manual and measure/check the pv-system
SMA!PV-Overvoltage!Overvoltage DCDisconnect DC, check the manual and measure/check the pv-system
SMABfr-SrrError AC-sideContact inverter service
SMAFac-BfrError AC-sideContact inverter service
SMAFac-SrrError AC-sideContact inverter service
SMAFacFastError AC-sideContact inverter service
SMAImax/overcurrentOvervoltage ACContact inverter service
SMAK1-closeInternal faultContact inverter service
SMAK1-openInternal faultContact inverter service
SMARisoInstallation problemCheck the manual and measure/check the pv-system
SMAVac-BfrOvervoltage DCContact inverter service
SMAVac-SrrOvervoltage DCContact inverter service
SMA101-103Grid errorCheck the manual and measure/check the pv-system
SMA202-205Grid errorCheck the manual and measure/check the pv-system
SMA301Grid errorCheck the manual and measure/check the pv-system
SMA401-404Grid errorCheck the manual and measure/check the pv-system
SMA501Grid errorCheck the manual and measure/check the pv-system
SMA601Grid errorCheck the manual and measure/check the pv-system
SMA701Frequency out of rangeContact inverter service
SMA801Waiting for gridCheck the manual and measure/check the pv-system
SMA901No PE-connectionCheck the manual and measure/check the pv-system
SMA1001L-N swappedCheck the manual and measure/check the pv-system
SMA1101Installation problemCheck the manual and measure/check the pv-system
SMA3301-3303UnstableCheck the manual and measure/check the pv-system
SMA3401-3402Overvoltage DCContact inverter service
SMA3501InsulationContact inverter service
SMA3601Leaking CurrentContact inverter service
SMA3701Residential CurrentContact inverter service
SMA6001-6438self-diagnosisContact inverter service
SMA64self-diagnosisContact inverter service
SMA6438self-diagnosisContact inverter service
SMA6408self-diagnosisContact inverter service
SMA6427self-diagnosisContact inverter service
SMA6501-6502self-diagnosisCheck the manual and measure/check the pv-system
SMA6801-6802self-diagnosisContact inverter service
SMA6901-6902self-diagnosisContact inverter service
SMA7401Varistor problemContact inverter service
SMA7701self-diagnosisContact inverter service
SMA7702self-diagnosisContact inverter service
SMA7703self-diagnosisContact inverter service
SMA77self-diagnosisContact inverter service